The polyphenolic content and the antioxidant capacity of seven tannins with different botanical origin were measured with spectrophotometric methods (Folin-Ciocalteu, Total Polyphenols Index, DPPH, FRAP), HPLC (phloroglucinolysis), voltammetric analysis (Linear Sweep Voltammetry, LSV). The oxygen consumption rate (OCR) was measured in an oxygen saturated model wine solution, containing transition metals and metabisulphite, with a noninvasive luminescence-based technology. The results showed a high variability in polyphenolic concentration related to the botanical origin of tannins. The OCR determined over 21 days was described by quadratic equations, with coefficients varying with tannin botanical origin, dose and SO2 concentration. The tannins ranked differently for antioxidant capacity, depending on the kind of test. The oxygen consumption parameters were positively correlated only with the LSV data measured with anodic current between 100 and 1200 mV (LSV1200mV) and with the FRAP index.

Relationship between polyphenolic content, antioxidant properties and oxygen consumption rate of different tannins in a model wine solution

Motta S.;Cassino C.;Bosso A.
2020-01-01

Abstract

The polyphenolic content and the antioxidant capacity of seven tannins with different botanical origin were measured with spectrophotometric methods (Folin-Ciocalteu, Total Polyphenols Index, DPPH, FRAP), HPLC (phloroglucinolysis), voltammetric analysis (Linear Sweep Voltammetry, LSV). The oxygen consumption rate (OCR) was measured in an oxygen saturated model wine solution, containing transition metals and metabisulphite, with a noninvasive luminescence-based technology. The results showed a high variability in polyphenolic concentration related to the botanical origin of tannins. The OCR determined over 21 days was described by quadratic equations, with coefficients varying with tannin botanical origin, dose and SO2 concentration. The tannins ranked differently for antioxidant capacity, depending on the kind of test. The oxygen consumption parameters were positively correlated only with the LSV data measured with anodic current between 100 and 1200 mV (LSV1200mV) and with the FRAP index.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11579/123243
Citazioni
  • ???jsp.display-item.citation.pmc??? 9
  • Scopus 24
  • ???jsp.display-item.citation.isi??? 20
social impact