BACKGROUND AND AIM: Ionizing radiation exposure from medical procedures is rising sharply-the per-capita annual effective dose in the US is 3.0 millisieverts (mSv). Hemodialyzed and kidney transplanted patients receive still higher doses of ionizing radiation due to the presence of multiple comorbidities. The aim of this study was to assess the cumulative effective dose (CED) among dialyzed patients undergoing renal pre-transplant evaluation. PATIENTS AND METHODS: We evaluated 70 hemodialysis patients between June 2009 and December 2014, aged 46.4 ± 12.0 years. The number and type of radiologic procedures were collected through the Radiology Information System. CED was expressed as total mSv/patient and annual CED (mSv/patient/year). RESULTS: A total of 744 radiologic procedures were performed, accounting for 3869 mSv of ionizing radiation: conventional radiology, computed tomography and nuclear medicine accounted for 78, 14 and 8 % of the procedures, but they represented, respectively, 8, 83 and 9 % of the total CED. The mean (median) annual CED was 35 (7) mSv/patient/year, while total CED was 72 (32) mSv/patient. Thirty-seven patients were active waitlisted and received 47 (10) mSv during the pre-transplant evaluation and 36 (5) mSv during the waiting phase to maintain active status. Concerning cancer risk, 4 (7 %) patients were classified at low risk (<3 mSv/year), 19 (35 %) at moderate risk (3 to <20 mSv/year), 8 (15 %) at high risk (20 to <50 mSv/year), and 23 (43 %) at very high risk (≥50 mSv/year). CONCLUSIONS: Our study demonstrated that during renal pre-transplant evaluation, dialyzed patients receive a high dose of ionizing radiation. Considering that transplanted individuals have a high incidence of cancer due to multifactorial etiology, it is mandatory to reduce the ionizing radiation imaging.

Radiation exposure from medical imaging in dialyzed patients undergoing renal pre-transplant evaluation

CARRIERO, Alessandro;
2017-01-01

Abstract

BACKGROUND AND AIM: Ionizing radiation exposure from medical procedures is rising sharply-the per-capita annual effective dose in the US is 3.0 millisieverts (mSv). Hemodialyzed and kidney transplanted patients receive still higher doses of ionizing radiation due to the presence of multiple comorbidities. The aim of this study was to assess the cumulative effective dose (CED) among dialyzed patients undergoing renal pre-transplant evaluation. PATIENTS AND METHODS: We evaluated 70 hemodialysis patients between June 2009 and December 2014, aged 46.4 ± 12.0 years. The number and type of radiologic procedures were collected through the Radiology Information System. CED was expressed as total mSv/patient and annual CED (mSv/patient/year). RESULTS: A total of 744 radiologic procedures were performed, accounting for 3869 mSv of ionizing radiation: conventional radiology, computed tomography and nuclear medicine accounted for 78, 14 and 8 % of the procedures, but they represented, respectively, 8, 83 and 9 % of the total CED. The mean (median) annual CED was 35 (7) mSv/patient/year, while total CED was 72 (32) mSv/patient. Thirty-seven patients were active waitlisted and received 47 (10) mSv during the pre-transplant evaluation and 36 (5) mSv during the waiting phase to maintain active status. Concerning cancer risk, 4 (7 %) patients were classified at low risk (<3 mSv/year), 19 (35 %) at moderate risk (3 to <20 mSv/year), 8 (15 %) at high risk (20 to <50 mSv/year), and 23 (43 %) at very high risk (≥50 mSv/year). CONCLUSIONS: Our study demonstrated that during renal pre-transplant evaluation, dialyzed patients receive a high dose of ionizing radiation. Considering that transplanted individuals have a high incidence of cancer due to multifactorial etiology, it is mandatory to reduce the ionizing radiation imaging.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11579/73322
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 7
social impact