BACKGROUND/AIMS: Recent evidences suggest that hemodialysis (HD) induces glycemic variations in diabetic patients. Continuous glucose monitoring (CGM) devices measure interstitial glucose in a 'Holter-like' manner thereby improving the glycemic control assessment method. METHODS: A CGM device (Medtronic iPRO) was used on 12 diabetic patients with chronic HD for 6 days to assess intra- and extra-dialytic interstitial glucose. RESULTS: In all enrolled patients, HD was associated with a decrease of interstitial glucose values. Intradialytic glucose nadir was 79 mg/dl and it was reached at the third hour after the beginning of the session. At the end of HD, interstitial glucose increased in all patients and a glycemic peak (187 mg/dl) occurred after an average time of 2.5 h. No episodes of nocturnal hypoglycemia occurred. CONCLUSION: HD is associated with significant intradialytic reduction of glycemia and postdialytic hyperglycemia. CGM devices result in better monitoring of glycemic trends in diabetic patients on chronic HD and could improve insulin management.

Glycemic pattern in diabetic patients on hemodialysis: continuous glucose monitoring (CGM) analysis

CANTALUPPI, Vincenzo;
2014-01-01

Abstract

BACKGROUND/AIMS: Recent evidences suggest that hemodialysis (HD) induces glycemic variations in diabetic patients. Continuous glucose monitoring (CGM) devices measure interstitial glucose in a 'Holter-like' manner thereby improving the glycemic control assessment method. METHODS: A CGM device (Medtronic iPRO) was used on 12 diabetic patients with chronic HD for 6 days to assess intra- and extra-dialytic interstitial glucose. RESULTS: In all enrolled patients, HD was associated with a decrease of interstitial glucose values. Intradialytic glucose nadir was 79 mg/dl and it was reached at the third hour after the beginning of the session. At the end of HD, interstitial glucose increased in all patients and a glycemic peak (187 mg/dl) occurred after an average time of 2.5 h. No episodes of nocturnal hypoglycemia occurred. CONCLUSION: HD is associated with significant intradialytic reduction of glycemia and postdialytic hyperglycemia. CGM devices result in better monitoring of glycemic trends in diabetic patients on chronic HD and could improve insulin management.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11579/71534
Citazioni
  • ???jsp.display-item.citation.pmc??? 13
  • Scopus 33
  • ???jsp.display-item.citation.isi??? 26
social impact