A fully automated system for on-line high-performance liquid chromatographic separation, reduction and determination by cold vapour atomic absorption spectrometry (CVAAS) of methyl-, ethyl-, phenyl- and inorganic mercury is described. Reversed-phase chromatography on an ODS column and elution with an acetonitrile-water-ammonium tetramethylenedithiocarbamate buffered mixture was investigated with or without ammonium tetramethylenedithiocarbamate precomplexation. A simple glass flow cell, properly designed as an interface between the chromatographic system and CVAAS, is proposed. The influence of the composition of the eluent, reducing solution and stripping gas flow-rate was investigated and optimized in order to obtain better detection limits. The method, applied to synthetic mixtures and natural samples of tap water furnished satisfactory results. It is shown that, with the on-line preconcentration procedure, sub-ng/ml concentration levels can be determined for all the species considered.

Simultaneous determination of methyl-, ethyl-, phenyl- and inorganic mercury by cold vapour atomic absorption spectrometry with on-line chromatographic separation

ACETO, Maurizio;
1992-01-01

Abstract

A fully automated system for on-line high-performance liquid chromatographic separation, reduction and determination by cold vapour atomic absorption spectrometry (CVAAS) of methyl-, ethyl-, phenyl- and inorganic mercury is described. Reversed-phase chromatography on an ODS column and elution with an acetonitrile-water-ammonium tetramethylenedithiocarbamate buffered mixture was investigated with or without ammonium tetramethylenedithiocarbamate precomplexation. A simple glass flow cell, properly designed as an interface between the chromatographic system and CVAAS, is proposed. The influence of the composition of the eluent, reducing solution and stripping gas flow-rate was investigated and optimized in order to obtain better detection limits. The method, applied to synthetic mixtures and natural samples of tap water furnished satisfactory results. It is shown that, with the on-line preconcentration procedure, sub-ng/ml concentration levels can be determined for all the species considered.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11579/48161
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 45
  • ???jsp.display-item.citation.isi??? 34
social impact