We compared two strategies for minimal residual disease evaluation of B-cell lymphoproliferative disorders characterized by a variable immunoglobulin heavy chain (IGH) genes mutation load. Twenty-five samples from chronic lymphocytic leukaemia (n = 18) or mantle cell lymphoma (n = 7) patients were analyzed. Based on IGH variable region genes, 22/25 samples carried >2% mutations, 20/25 > 5%. In the IGH joining region genes, 23/25 samples carried >2% mutations, 18/25 > 5%. Real-time quantitative polymerase chain reaction was performed on IGH genes using two strategies: method A utilizes two patient-specific primers, whereas method B employs one patient-specific and one germline primer, with different positions on the variable, diversity and joining regions. Twenty-three samples (92%) resulted evaluable using method A, only six (24%) by method B. Method B poor performance was specifically evident among mutated IGH variable/joining region cases, although no specific mutation load above, which the real-time quantitative polymerase chain reaction failed was found. The molecular strategies for minimal residual disease evaluation should be adapted to the B-cell receptor features of the disease investigated.

COMPARISON OF TWO REAL-TIME QUANTITATIVE POLYMERASE CHAIN REACTION STRATEGIES FOR MINIMAL RESIDUAL DISEASE EVALUATION IN LYMPHOPROLIFERATIVE DISORDERS: CORRELATION BETWEEN IMMUNOGLOBULIN GENE MUTATION LOAD AND REAL-TIME QUANTITATIVE POLYMERASE CHAIN REACTION PERFORMANCE

GAIDANO, Gianluca;Ladetto M;
2014-01-01

Abstract

We compared two strategies for minimal residual disease evaluation of B-cell lymphoproliferative disorders characterized by a variable immunoglobulin heavy chain (IGH) genes mutation load. Twenty-five samples from chronic lymphocytic leukaemia (n = 18) or mantle cell lymphoma (n = 7) patients were analyzed. Based on IGH variable region genes, 22/25 samples carried >2% mutations, 20/25 > 5%. In the IGH joining region genes, 23/25 samples carried >2% mutations, 18/25 > 5%. Real-time quantitative polymerase chain reaction was performed on IGH genes using two strategies: method A utilizes two patient-specific primers, whereas method B employs one patient-specific and one germline primer, with different positions on the variable, diversity and joining regions. Twenty-three samples (92%) resulted evaluable using method A, only six (24%) by method B. Method B poor performance was specifically evident among mutated IGH variable/joining region cases, although no specific mutation load above, which the real-time quantitative polymerase chain reaction failed was found. The molecular strategies for minimal residual disease evaluation should be adapted to the B-cell receptor features of the disease investigated.
File in questo prodotto:
File Dimensione Formato  
Comparison of two real-time quantitative polymerase chain reaction strategies for minimal residual disease evaluation in lymphoproliferative disorders correlation between immunoglobulin gene mutation load and real_time quantitati.pdf

file disponibile solo agli amministratori

Tipologia: Altro materiale allegato
Licenza: DRM non definito
Dimensione 191.35 kB
Formato Adobe PDF
191.35 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11579/39401
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 8
social impact