We compared two strategies for minimal residual disease evaluation of B-cell lymphoproliferative disorders characterized by a variable immunoglobulin heavy chain (IGH) genes mutation load. Twenty-five samples from chronic lymphocytic leukaemia (n = 18) or mantle cell lymphoma (n = 7) patients were analyzed. Based on IGH variable region genes, 22/25 samples carried >2% mutations, 20/25 > 5%. In the IGH joining region genes, 23/25 samples carried >2% mutations, 18/25 > 5%. Real-time quantitative polymerase chain reaction was performed on IGH genes using two strategies: method A utilizes two patient-specific primers, whereas method B employs one patient-specific and one germline primer, with different positions on the variable, diversity and joining regions. Twenty-three samples (92%) resulted evaluable using method A, only six (24%) by method B. Method B poor performance was specifically evident among mutated IGH variable/joining region cases, although no specific mutation load above, which the real-time quantitative polymerase chain reaction failed was found. The molecular strategies for minimal residual disease evaluation should be adapted to the B-cell receptor features of the disease investigated.
COMPARISON OF TWO REAL-TIME QUANTITATIVE POLYMERASE CHAIN REACTION STRATEGIES FOR MINIMAL RESIDUAL DISEASE EVALUATION IN LYMPHOPROLIFERATIVE DISORDERS: CORRELATION BETWEEN IMMUNOGLOBULIN GENE MUTATION LOAD AND REAL-TIME QUANTITATIVE POLYMERASE CHAIN REACTION PERFORMANCE
GAIDANO, Gianluca;Ladetto M;
2014-01-01
Abstract
We compared two strategies for minimal residual disease evaluation of B-cell lymphoproliferative disorders characterized by a variable immunoglobulin heavy chain (IGH) genes mutation load. Twenty-five samples from chronic lymphocytic leukaemia (n = 18) or mantle cell lymphoma (n = 7) patients were analyzed. Based on IGH variable region genes, 22/25 samples carried >2% mutations, 20/25 > 5%. In the IGH joining region genes, 23/25 samples carried >2% mutations, 18/25 > 5%. Real-time quantitative polymerase chain reaction was performed on IGH genes using two strategies: method A utilizes two patient-specific primers, whereas method B employs one patient-specific and one germline primer, with different positions on the variable, diversity and joining regions. Twenty-three samples (92%) resulted evaluable using method A, only six (24%) by method B. Method B poor performance was specifically evident among mutated IGH variable/joining region cases, although no specific mutation load above, which the real-time quantitative polymerase chain reaction failed was found. The molecular strategies for minimal residual disease evaluation should be adapted to the B-cell receptor features of the disease investigated.File | Dimensione | Formato | |
---|---|---|---|
Comparison of two real-time quantitative polymerase chain reaction strategies for minimal residual disease evaluation in lymphoproliferative disorders correlation between immunoglobulin gene mutation load and real_time quantitati.pdf
file disponibile solo agli amministratori
Tipologia:
Altro materiale allegato
Licenza:
DRM non definito
Dimensione
191.35 kB
Formato
Adobe PDF
|
191.35 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.