Results of a study conducted to assess the degree of airborne bacterial contamination generated by two wastewater treatment plants (WWTP) with different treatment systems and evaluate the dispersion of potential pathogens, have been described. Aerosols samples were collected in summer and winter with an agar impact sampler from several plant sites. External upwind and downwind controls were also examined. Total colony-forming counts of mesophilic and thermophilic bacteria, actinomycetes and streptomycetes, Gram- negatives, coliforms and sulfite-reducers were determined. Selective media were used in order to detect pathogenic bacteria. The lowest concentrations of mesophilic and thermophilic bacteria were 8 and 28CFU/m3 in plants A and B respectively, the highest 440000CFU/m3 in both plants. Strains of Escherichia coli, Clostridium perfringens, Staphylococcus aureus and Enterococcus spp. were isolated in some sites of the two plants. Salmonella spp., Yersinia enterocolitica and Legionella spp. were never detected. The activities involving nebulization and mechanical aeration of wastewaters and the sewage inflows have proved to be of greatest potential risk. In both plants, we found a statistically significant dependence of bacterial contamination on the season for many of the analyzed parameters but a clear seasonal trend could not be observed.

Site-related airborne biological hazard and seasonal variations in two wastewater treatment plants

FRACCHIA, Letizia;PIETRONAVE, STEFANO;RINALDI, Maurizio;
2006-01-01

Abstract

Results of a study conducted to assess the degree of airborne bacterial contamination generated by two wastewater treatment plants (WWTP) with different treatment systems and evaluate the dispersion of potential pathogens, have been described. Aerosols samples were collected in summer and winter with an agar impact sampler from several plant sites. External upwind and downwind controls were also examined. Total colony-forming counts of mesophilic and thermophilic bacteria, actinomycetes and streptomycetes, Gram- negatives, coliforms and sulfite-reducers were determined. Selective media were used in order to detect pathogenic bacteria. The lowest concentrations of mesophilic and thermophilic bacteria were 8 and 28CFU/m3 in plants A and B respectively, the highest 440000CFU/m3 in both plants. Strains of Escherichia coli, Clostridium perfringens, Staphylococcus aureus and Enterococcus spp. were isolated in some sites of the two plants. Salmonella spp., Yersinia enterocolitica and Legionella spp. were never detected. The activities involving nebulization and mechanical aeration of wastewaters and the sewage inflows have proved to be of greatest potential risk. In both plants, we found a statistically significant dependence of bacterial contamination on the season for many of the analyzed parameters but a clear seasonal trend could not be observed.
File in questo prodotto:
File Dimensione Formato  
Fracchia et al., 2006 WR.pdf

file disponibile solo agli amministratori

Tipologia: Altro materiale allegato
Licenza: DRM non definito
Dimensione 564.18 kB
Formato Adobe PDF
564.18 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11579/31881
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 80
  • ???jsp.display-item.citation.isi??? 72
social impact