: To evaluate efficacy and safety of continuous glucose monitoring (CGM) and automated insulin delivery (AID) in infants. A retrospective multicenter study (13 centers) of 76 children diagnosed with antibody-positive type 1 diabetes before age 2. Outcomes at 12 months were compared between AID users (n = 47) and multiple daily injections (MDI)/SAP users (n = 29). AID systems included Medtronic 780 G (38%), Tandem Control-IQ (38%), and CamAPS FX (24%). CGM median wear time was 97.0% (93.3; 98.1). AID users achieved significantly higher TIR (65% vs. 56%, P = 0.041) and time in tight range (TITR) (42% vs 32.5%, P = 0.038). In multivariable regression, AID was the sole independent predictor of lower HbA1c (P = 0.035). Zero severe hypoglycemia (SH) events occurred in the AID group (vs. 7.1% in MDI/SAP). Use of CGM is safe in very young children, with AID systems proving superior to traditional therapy. This real-world evidence supports incorporating AID consideration into future international guidelines from the time of pediatric diagnosis.
Continuous Glucose Monitoring and Automated Insulin Delivery in Infants with Type 1 Diabetes: Real-World Evidence to Support Future International Guidelines
Rabbone, Ivana;
In corso di stampa
Abstract
: To evaluate efficacy and safety of continuous glucose monitoring (CGM) and automated insulin delivery (AID) in infants. A retrospective multicenter study (13 centers) of 76 children diagnosed with antibody-positive type 1 diabetes before age 2. Outcomes at 12 months were compared between AID users (n = 47) and multiple daily injections (MDI)/SAP users (n = 29). AID systems included Medtronic 780 G (38%), Tandem Control-IQ (38%), and CamAPS FX (24%). CGM median wear time was 97.0% (93.3; 98.1). AID users achieved significantly higher TIR (65% vs. 56%, P = 0.041) and time in tight range (TITR) (42% vs 32.5%, P = 0.038). In multivariable regression, AID was the sole independent predictor of lower HbA1c (P = 0.035). Zero severe hypoglycemia (SH) events occurred in the AID group (vs. 7.1% in MDI/SAP). Use of CGM is safe in very young children, with AID systems proving superior to traditional therapy. This real-world evidence supports incorporating AID consideration into future international guidelines from the time of pediatric diagnosis.| File | Dimensione | Formato | |
|---|---|---|---|
|
marigliano-et-al-2026-continuous-glucose-monitoring-and-automated-insulin-delivery-in-infants-with-type-1-diabetes-real.pdf
file disponibile agli utenti autorizzati
Licenza:
Copyright dell'editore
Dimensione
628.61 kB
Formato
Adobe PDF
|
628.61 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.