Objectives: To evaluate the safety and efficacy of the Orsiro sirolimus-eluting stent (Biotronik) in patients with ST-segment elevation myocardial infarction undergoing primary percutaneous coronary intervention (pPCI). Specific drug-eluting stent (DES) platforms might influence pPCI success rate in the mid-to-long term. Orsiro, a hybrid sirolimus DES with thin struts and a biodegradable polymer, may potentially cause less stent malapposition, stent-induced inflammation, and mechanical damage, improving clinical outcomes. Methods: We retrospectively enrolled all patients who received 1 or more Orsiro DES in the target vessel of pPCI at 9 Italian centers from January 2012 to March 2016. The primary endpoint was a device-oriented composite endpoint (DOCE) of cardiac death, any myocardial infarction clearly attributable to the intervention culprit vessel (TVMI), and ischemic-driven target-lesion revascularization (ID-TLR) at 1-year follow-up. Secondary endpoints were: (1) DOCE at 6-month and 3-year follow-up; (2) any definite/probable stent thrombosis; and (3) any major bleeding. Results: The study cohort comprised 353 patients. At 1-year follow-up, we observed a 3.7% cumulative incidence of DOCE, consisting of 11 cardiac deaths (3.1%), 2 TVMIs (0.6%), and 2 ID-TLRs (0.6%). There was only 1 definite stent thrombosis (0.3%) and 8 bleedings (2.4%). Kaplan-Meier analysis showed DOCE-free survival rates of 96.6% at 6 months, 96.3% at 1 year, and 93.8% at 3 years. Conclusions: Our findings support the real-world safety and efficacy of the Orsiro stent for pPCI.
Hard Events AfteR Orsiro Sirolimus-Eluting Stent (HEROES) in STEMI: A Multicenter Registry
D'Amario, Domenico;Annibali, Gianmarco;Vergallo, Rocco;
2020-01-01
Abstract
Objectives: To evaluate the safety and efficacy of the Orsiro sirolimus-eluting stent (Biotronik) in patients with ST-segment elevation myocardial infarction undergoing primary percutaneous coronary intervention (pPCI). Specific drug-eluting stent (DES) platforms might influence pPCI success rate in the mid-to-long term. Orsiro, a hybrid sirolimus DES with thin struts and a biodegradable polymer, may potentially cause less stent malapposition, stent-induced inflammation, and mechanical damage, improving clinical outcomes. Methods: We retrospectively enrolled all patients who received 1 or more Orsiro DES in the target vessel of pPCI at 9 Italian centers from January 2012 to March 2016. The primary endpoint was a device-oriented composite endpoint (DOCE) of cardiac death, any myocardial infarction clearly attributable to the intervention culprit vessel (TVMI), and ischemic-driven target-lesion revascularization (ID-TLR) at 1-year follow-up. Secondary endpoints were: (1) DOCE at 6-month and 3-year follow-up; (2) any definite/probable stent thrombosis; and (3) any major bleeding. Results: The study cohort comprised 353 patients. At 1-year follow-up, we observed a 3.7% cumulative incidence of DOCE, consisting of 11 cardiac deaths (3.1%), 2 TVMIs (0.6%), and 2 ID-TLRs (0.6%). There was only 1 definite stent thrombosis (0.3%) and 8 bleedings (2.4%). Kaplan-Meier analysis showed DOCE-free survival rates of 96.6% at 6 months, 96.3% at 1 year, and 93.8% at 3 years. Conclusions: Our findings support the real-world safety and efficacy of the Orsiro stent for pPCI.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.