The aims of this study were as follows: (1) To evaluate the entheseal fibrocartilage (EF) during Achilles tendon insertion in patients with Psoriatic Arthritis (PsA) by using power Doppler ultrasound (PDUS), (2) to assess the intra and inter-reader reliability of the evaluation of EF thickness, (3) to compare the EF thickness of PsA patients, athletes and healthy controls (HCs), and (4) to evaluate the correlations between EF abnormalities, disease activity and functional indices in PsA. Methods: Consecutive PsA patients attending our unit were asked to participate. HCs and agonist athletes were enrolled as a control group. A bilateral PDUS evaluation of Achilles tendons was performed in order to evaluate the EF in all patients and controls. Results: In total, 30 PsA patients, 40 athletes and 20 HCs were enrolled. The median (IQR) EF thickness among the PsA patients, athletes and HCs was 0.035 cm (0.028–0.04) cm, 0.036 (0.025–0.043) cm and 0.030 (0.020–0.038) cm, respectively (p = 0.05 between PsA patients and HCs). The intra-reader reliability was excellent [ICC (95% CI) of 0.91 (0.88–0.95)] and the inter-reader reliability was good (0.80 (0.71–0.86). The assessment of EF was feasible, with a mean time of 2 min. No correlations were found with disease activity indices in PsA patients. Conclusion: The assessment of EF is a feasible and reproducible test and may be explored as a potential imaging biomarker.

Ultrasonographic Evaluation of Entheseal Fibrocartilage in Patients with Psoriatic Arthritis, Athletes and Healthy Controls: A Comparison Study

Ronga M.;
2023-01-01

Abstract

The aims of this study were as follows: (1) To evaluate the entheseal fibrocartilage (EF) during Achilles tendon insertion in patients with Psoriatic Arthritis (PsA) by using power Doppler ultrasound (PDUS), (2) to assess the intra and inter-reader reliability of the evaluation of EF thickness, (3) to compare the EF thickness of PsA patients, athletes and healthy controls (HCs), and (4) to evaluate the correlations between EF abnormalities, disease activity and functional indices in PsA. Methods: Consecutive PsA patients attending our unit were asked to participate. HCs and agonist athletes were enrolled as a control group. A bilateral PDUS evaluation of Achilles tendons was performed in order to evaluate the EF in all patients and controls. Results: In total, 30 PsA patients, 40 athletes and 20 HCs were enrolled. The median (IQR) EF thickness among the PsA patients, athletes and HCs was 0.035 cm (0.028–0.04) cm, 0.036 (0.025–0.043) cm and 0.030 (0.020–0.038) cm, respectively (p = 0.05 between PsA patients and HCs). The intra-reader reliability was excellent [ICC (95% CI) of 0.91 (0.88–0.95)] and the inter-reader reliability was good (0.80 (0.71–0.86). The assessment of EF was feasible, with a mean time of 2 min. No correlations were found with disease activity indices in PsA patients. Conclusion: The assessment of EF is a feasible and reproducible test and may be explored as a potential imaging biomarker.
File in questo prodotto:
File Dimensione Formato  
Perrotta et al. diagnostics-13-01446 EF in PsA.pdf

file disponibile solo agli amministratori

Dimensione 1.06 MB
Formato Adobe PDF
1.06 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11579/160111
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 1
social impact