Background: Innovative customized computer-aided design/computer-assisted manufacture (CAD-CAM) titanium meshes have been proposed for guided alveolar bone regeneration. Histological confirmation on the quality of the regenerated bone is needed. Purpose of the study is to assess the integration capabilities of these innovative meshes and to evaluate the histological features of the regenerated alveolar bone. Materials and methods: Twenty partially edentulous patients, with severe posterior mandibular atrophy, underwent a guided bone regeneration technique by means of customized CAD-CAM titanium mesh in association with a mixture of autologous bone in chips and deproteinized bovine bone (1:1). At 9 months of healing, titanium meshes and bone samples were collected and histomorphometrically analyzed. Results: In all patients, implants were placed according to the original plan. At histologic analysis, mesh appeared well osseointegrated, except that in sites where membrane exposure occurred. In all sites, newly formed tissue resulted highly mineralized, well-organized, and formed by 35.88% of new lamellar bone, 16.42% of woven bone, 10.88% of osteoid matrix, 14.10% of grafted remnants, and 22.72% of medullary spaces. Blood vessels were the 4% of the tissue. Conclusions: Data from this study support the use of customized CAD/CAM titanium mesh for regeneration of vital, well-structured, and vascularized alveolar bone.

Histological assessment of mandibular bone tissue after guided bone regeneration with customized computer-aided design/computer-assisted manufacture titanium mesh in humans: A cohort study

Canciani E
Secondo
;
2021-01-01

Abstract

Background: Innovative customized computer-aided design/computer-assisted manufacture (CAD-CAM) titanium meshes have been proposed for guided alveolar bone regeneration. Histological confirmation on the quality of the regenerated bone is needed. Purpose of the study is to assess the integration capabilities of these innovative meshes and to evaluate the histological features of the regenerated alveolar bone. Materials and methods: Twenty partially edentulous patients, with severe posterior mandibular atrophy, underwent a guided bone regeneration technique by means of customized CAD-CAM titanium mesh in association with a mixture of autologous bone in chips and deproteinized bovine bone (1:1). At 9 months of healing, titanium meshes and bone samples were collected and histomorphometrically analyzed. Results: In all patients, implants were placed according to the original plan. At histologic analysis, mesh appeared well osseointegrated, except that in sites where membrane exposure occurred. In all sites, newly formed tissue resulted highly mineralized, well-organized, and formed by 35.88% of new lamellar bone, 16.42% of woven bone, 10.88% of osteoid matrix, 14.10% of grafted remnants, and 22.72% of medullary spaces. Blood vessels were the 4% of the tissue. Conclusions: Data from this study support the use of customized CAD/CAM titanium mesh for regeneration of vital, well-structured, and vascularized alveolar bone.
File in questo prodotto:
File Dimensione Formato  
3 - 2021 Clin Implant Dent Rel Res.pdf

file disponibile solo agli amministratori

Tipologia: Versione Editoriale (PDF)
Licenza: Copyright dell'editore
Dimensione 2.87 MB
Formato Adobe PDF
2.87 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11579/156102
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 40
  • ???jsp.display-item.citation.isi??? 30
social impact