BACKGROUNDThe fluid challenge response in surgical patients can be predicted by functional haemodynamic tests. Two tests, the mini-fluid challenge (mini-FC) and end-expiratory occlusion test (EEOT), have been assessed in a few small single-centre studies with conflicting results. In general, functional haemodynamic tests have not performed reliably in predicting fluid responsiveness in patients undergoing laparotomy.OBJECTIVEThis trial is designed to address and compare the reliability of the EEOT and the mini-FC in predicting fluid responsiveness during laparotomy.DESIGNProspective, multicentre study.SETTINGThree university hospitals in Italy.PATIENTSA total of 103 adults patients scheduled for elective laparotomy with invasive arterial monitoring.INTERVENTIONSThe study protocol evaluated the changes in the stroke volume index (SVI) 20s (EEOT20) and 30s (EEOT30) after an expiratory hold and after a mini-FC of 100ml over 1min. Fluid responsiveness required an increase in SVI at least 10% following 4mlkg-1of Ringer's solution fluid challenge infused over 10min.MAIN OUTCOME MEASUREMENTSHaemodynamic data, including SVI, were obtained from pulse contour analysis. The area under the receiver operating characteristic curves of the tests were compared with assess fluid responsiveness.RESULTSFluid challenge administration induced an increase in SVI at least 10% in 51.5% of patients. The rate of fluid responsiveness was comparable among the three participant centres (P=0.10). The area under the receiver operating characteristic curves (95% CI) of the changes in SVI after mini-FC was 0.95 (0.88 to 0.98), sensitivity 98.0% (89.5 to 99.6) and specificity 86.8% (75.1 to 93.4) for a cut-off value of 4% of increase in SVI. This was higher than the SVI changes after EEOT20, 0.67 (0.57 to 0.76) and after EEOT30, 0.73 (0.63 to 0.81).CONCLUSIONIn patients undergoing laparotomy the mini-FC reliably predicted fluid responsiveness with high-sensitivity and specificity. The EEOT showed poor discriminative value and cannot be recommended for assessment of fluid responsiveness in this surgical setting.TRIAL REGISTRATIONNCT03808753.
Mini fluid chAllenge and End-expiratory occlusion test to assess flUid responsiVEness in the opeRating room (MANEUVER study): A multicentre cohort study
Cammarota G.;
2021-01-01
Abstract
BACKGROUNDThe fluid challenge response in surgical patients can be predicted by functional haemodynamic tests. Two tests, the mini-fluid challenge (mini-FC) and end-expiratory occlusion test (EEOT), have been assessed in a few small single-centre studies with conflicting results. In general, functional haemodynamic tests have not performed reliably in predicting fluid responsiveness in patients undergoing laparotomy.OBJECTIVEThis trial is designed to address and compare the reliability of the EEOT and the mini-FC in predicting fluid responsiveness during laparotomy.DESIGNProspective, multicentre study.SETTINGThree university hospitals in Italy.PATIENTSA total of 103 adults patients scheduled for elective laparotomy with invasive arterial monitoring.INTERVENTIONSThe study protocol evaluated the changes in the stroke volume index (SVI) 20s (EEOT20) and 30s (EEOT30) after an expiratory hold and after a mini-FC of 100ml over 1min. Fluid responsiveness required an increase in SVI at least 10% following 4mlkg-1of Ringer's solution fluid challenge infused over 10min.MAIN OUTCOME MEASUREMENTSHaemodynamic data, including SVI, were obtained from pulse contour analysis. The area under the receiver operating characteristic curves of the tests were compared with assess fluid responsiveness.RESULTSFluid challenge administration induced an increase in SVI at least 10% in 51.5% of patients. The rate of fluid responsiveness was comparable among the three participant centres (P=0.10). The area under the receiver operating characteristic curves (95% CI) of the changes in SVI after mini-FC was 0.95 (0.88 to 0.98), sensitivity 98.0% (89.5 to 99.6) and specificity 86.8% (75.1 to 93.4) for a cut-off value of 4% of increase in SVI. This was higher than the SVI changes after EEOT20, 0.67 (0.57 to 0.76) and after EEOT30, 0.73 (0.63 to 0.81).CONCLUSIONIn patients undergoing laparotomy the mini-FC reliably predicted fluid responsiveness with high-sensitivity and specificity. The EEOT showed poor discriminative value and cannot be recommended for assessment of fluid responsiveness in this surgical setting.TRIAL REGISTRATIONNCT03808753.File | Dimensione | Formato | |
---|---|---|---|
Mini_fluid_chAllenge_aNd_End_expiratory_occlusion.13.pdf
file disponibile solo agli amministratori
Dimensione
477.32 kB
Formato
Adobe PDF
|
477.32 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.