Immune checkpoint inhibitors for blocking the programmed cell death protein 1 (PD- 1)/programmed death-ligand 1 (PD-L1) axis are now available for squamous cell carcinoma of the head and neck (HNSCC) in relapsing and/or metastatic settings. In this work, we compared the resulting combined positive score (CPS) of PD-L1 using alternative methods adopted in routine clinical practice and determined the level of diagnostic agreement and inter-observer reliability in this setting. The study applied 5 different protocols on 40 tissue microarrays from HNSCC. The error rate of the individual protocols ranged from a minimum of 7% to a maximum of 21%, the sensitivity from 79% to 96%, and the specificity from 50% to 100%. In the intermediate group (1 ≤ CPS < 20), the majority of errors consisted of an underestimation of PD-L1 expression. In strong expressors, 5 out of 14 samples (36%) were correctly evaluated by all the protocols, but no protocol was able to correctly identify all the “strong expressors”. The overall inter-observer agreement in PD-L1 CPS reached 87%. The inter-observer reliability was moderate, with an ICC of 0.774 (95% CI (0.651; 0.871)). In conclusion, our study showed moderate interobserver reliability among different protocols. In order to improve the performances, adequate specific training to evaluate PD-L1 by CPS in the HNSCC setting should be coordinated.

PD-L1 testing and squamous cell carcinoma of the head and neck: A multicenter study on the diagnostic reproducibility of different protocols

Boldorini R.;
2021-01-01

Abstract

Immune checkpoint inhibitors for blocking the programmed cell death protein 1 (PD- 1)/programmed death-ligand 1 (PD-L1) axis are now available for squamous cell carcinoma of the head and neck (HNSCC) in relapsing and/or metastatic settings. In this work, we compared the resulting combined positive score (CPS) of PD-L1 using alternative methods adopted in routine clinical practice and determined the level of diagnostic agreement and inter-observer reliability in this setting. The study applied 5 different protocols on 40 tissue microarrays from HNSCC. The error rate of the individual protocols ranged from a minimum of 7% to a maximum of 21%, the sensitivity from 79% to 96%, and the specificity from 50% to 100%. In the intermediate group (1 ≤ CPS < 20), the majority of errors consisted of an underestimation of PD-L1 expression. In strong expressors, 5 out of 14 samples (36%) were correctly evaluated by all the protocols, but no protocol was able to correctly identify all the “strong expressors”. The overall inter-observer agreement in PD-L1 CPS reached 87%. The inter-observer reliability was moderate, with an ICC of 0.774 (95% CI (0.651; 0.871)). In conclusion, our study showed moderate interobserver reliability among different protocols. In order to improve the performances, adequate specific training to evaluate PD-L1 by CPS in the HNSCC setting should be coordinated.
File in questo prodotto:
File Dimensione Formato  
cancers-13-00292.pdf

file disponibile agli utenti autorizzati

Licenza: DRM non definito
Dimensione 1.9 MB
Formato Adobe PDF
1.9 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11579/124259
Citazioni
  • ???jsp.display-item.citation.pmc??? 10
  • Scopus 44
  • ???jsp.display-item.citation.isi??? 42
social impact