Background: Innovative approaches to improve diagnostic yield of endoscopic ultrasound-guided tissue acquisition (EUS-TA) have focused on needle design with development of fine-needle biopsy (FNB) needles with microcore-acquisition technology. Recently, a 20-gauge (20G) antegrade-cutting-side-bevelled biopsy needle (ProCore®) was developed for EUS-TA, but data about its diagnostic performance and histological capability are scant. Objectives: We assessed the diagnostic performance and histologic retrieval rate of a new 20G antegrade-cutting-side-bevelled biopsy needle compared with a 22G reverse-side-bevelled needle for EUS sampling of solid pancreatic lesions. Patients and methods: A retrospective analysis of 238 consecutively collected patients who underwent EUS-TA using a 20G or a 22G ProCore® needle, without rapid on-site evaluation (ROSE), was conducted at two centres.Sensitivity, specificity, positive predictive value and negative predictive value were calculated. Histologic tissue retrieval was evaluated applying a scoring system for each case. Results: Sensitivity and specificity were estimated as 98.4-100% in the 20G-, and 94.9-100% in the 22G-needle groups, respectively (p > 0.99). The 20G procured more histologic-grade tissues (92.6% vs 49.5%, p < 0.0001) achieved by a lower number of passes (2.64 vs 3.44, p < 0.0001) compared to the 22G. Conclusions: Both side-bevelled FNB needles achieved a high diagnostic sensitivity. The 20G-side-bevelled needle obtained a significantly higher microcore retrieval rate.

Histologic retrieval rate of a newly designed side-bevelled 20G needle for EUS-guided tissue acquisition of solid pancreatic lesions

Trisolini E.;Andorno S.;Boldorini R. L.;Occhipinti, Pietro;
2019-01-01

Abstract

Background: Innovative approaches to improve diagnostic yield of endoscopic ultrasound-guided tissue acquisition (EUS-TA) have focused on needle design with development of fine-needle biopsy (FNB) needles with microcore-acquisition technology. Recently, a 20-gauge (20G) antegrade-cutting-side-bevelled biopsy needle (ProCore®) was developed for EUS-TA, but data about its diagnostic performance and histological capability are scant. Objectives: We assessed the diagnostic performance and histologic retrieval rate of a new 20G antegrade-cutting-side-bevelled biopsy needle compared with a 22G reverse-side-bevelled needle for EUS sampling of solid pancreatic lesions. Patients and methods: A retrospective analysis of 238 consecutively collected patients who underwent EUS-TA using a 20G or a 22G ProCore® needle, without rapid on-site evaluation (ROSE), was conducted at two centres.Sensitivity, specificity, positive predictive value and negative predictive value were calculated. Histologic tissue retrieval was evaluated applying a scoring system for each case. Results: Sensitivity and specificity were estimated as 98.4-100% in the 20G-, and 94.9-100% in the 22G-needle groups, respectively (p > 0.99). The 20G procured more histologic-grade tissues (92.6% vs 49.5%, p < 0.0001) achieved by a lower number of passes (2.64 vs 3.44, p < 0.0001) compared to the 22G. Conclusions: Both side-bevelled FNB needles achieved a high diagnostic sensitivity. The 20G-side-bevelled needle obtained a significantly higher microcore retrieval rate.
File in questo prodotto:
File Dimensione Formato  
Histologic retrieval rate of a newly designed side-bevelled 20G needle for EUS-guided tissue acquisition of solid pancreatic lesions - Armellini E et al.pdf

file disponibile agli utenti autorizzati

Licenza: DRM non definito
Dimensione 638.67 kB
Formato Adobe PDF
638.67 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11579/103670
Citazioni
  • ???jsp.display-item.citation.pmc??? 21
  • Scopus 35
  • ???jsp.display-item.citation.isi??? 39